first commit
This commit is contained in:
@@ -0,0 +1,96 @@
|
||||
-- assumptions:
|
||||
-- the setpoint is set by a selector dummy device where the values are numeric temperatures
|
||||
-- but you can easily change it to a setpoint device
|
||||
|
||||
local BOILER_DEVICE = 'Boiler' -- switch device
|
||||
local SETPOINT_DEVICE = 'Setpoint' -- selector dummy device
|
||||
local TEMPERATURE_SENSOR = 'Temperature'
|
||||
local HYSTERESIS = 0.5 -- temp has to drop this value below setpoint before boiler is on again
|
||||
local SMOOTH_FACTOR = 3
|
||||
local LOGGING = true
|
||||
|
||||
return {
|
||||
on = {
|
||||
['timer'] = {
|
||||
'every minute',
|
||||
},
|
||||
devices = {
|
||||
TEMPERATURE_SENSOR,
|
||||
SETPOINT_DEVICE
|
||||
}
|
||||
},
|
||||
data = {
|
||||
temperatureReadings = { history = true, maxItems = SMOOTH_FACTOR }
|
||||
},
|
||||
active = true,
|
||||
execute = function(domoticz, item)
|
||||
|
||||
local avgTemp
|
||||
local temperatureReadings = domoticz.data.temperatureReadings
|
||||
local sensor = domoticz.devices(TEMPERATURE_SENSOR)
|
||||
local current = sensor.temperature
|
||||
local boiler = domoticz.devices(BOILER_DEVICE)
|
||||
local setpoint = domoticz.devices(SETPOINT_DEVICE)
|
||||
|
||||
-- first check if the sensor got a new reading or the setpoint was changed:
|
||||
if (item.isDevice) then
|
||||
|
||||
if (sensor.changed) then
|
||||
-- sensor just reported a new reading
|
||||
-- add it to the readings table
|
||||
|
||||
if (current ~= 0 and current ~= nil) then
|
||||
temperatureReadings.add(current)
|
||||
else
|
||||
-- no need to be here, weird state detected
|
||||
domoticz.log('Strange sensor reading.. skiping', domoticz.LOG_ERROR)
|
||||
return
|
||||
end
|
||||
|
||||
elseif (domoticz.devices(SETPOINT_DEVICE).changed) then
|
||||
-- a new setpoint was set
|
||||
if LOGGING then domoticz.log('Setpoint was set to ' .. item.state) end
|
||||
else
|
||||
-- no business here, bail out...
|
||||
return
|
||||
end
|
||||
end
|
||||
|
||||
-- now determine what to do
|
||||
if (setpoint.state == nil or setpoint.state == 'Off') then
|
||||
boiler.switchOff()
|
||||
return -- we're done here
|
||||
end
|
||||
|
||||
local setpointValue = tonumber(setpoint.state)
|
||||
|
||||
-- determine at which temperature the boiler should be
|
||||
-- switched on
|
||||
local switchOnTemp = setpointValue - HYSTERESIS
|
||||
|
||||
-- don't use the current reading but average it out over
|
||||
-- the past <SMOOTH_FACTOR> readings (data smoothing) to get rid of noise, wrong readings etc
|
||||
local avgTemp = temperatureReadings.avg(1, SMOOTH_FACTOR, current) -- fallback to current when history is empty
|
||||
|
||||
if LOGGING then
|
||||
domoticz.log('Average: ' .. avgTemp, domoticz.LOG_INFO)
|
||||
domoticz.log('Setpoint: ' .. setpointValue, domoticz.LOG_INFO)
|
||||
domoticz.log('Current boiler state: ' .. boiler.state, domoticz.LOG_INFO)
|
||||
domoticz.log('Switch-on temperature: ' .. switchOnTemp, domoticz.LOG_INFO)
|
||||
end
|
||||
|
||||
if (avgTemp >= setpointValue and boiler.state == 'On') then
|
||||
if LOGGING then domoticz.log('Target temperature reached, boiler off') end
|
||||
boiler.switchOff()
|
||||
end
|
||||
|
||||
if (avgTemp < setpointValue and boiler.state == 'Off') then
|
||||
if (avgTemp < switchOnTemp) then
|
||||
if LOGGING then domoticz.log('Heating is required, boiler switched on') end
|
||||
boiler.switchOn()
|
||||
else
|
||||
if LOGGING then domoticz.log('Average temperature below setpoint but within hysteresis range, waiting for temperature to drop to ' .. switchOnTemp) end
|
||||
end
|
||||
end
|
||||
end
|
||||
}
|
||||