-- assumptions:
|
|
-- the setpoint is set by a selector dummy device where the values are numeric temperatures
|
|
-- but you can easily change it to a setpoint device
|
|
|
|
local BOILER_DEVICE = 'Boiler' -- switch device
|
|
local SETPOINT_DEVICE = 'Setpoint' -- selector dummy device
|
|
local TEMPERATURE_SENSOR = 'Temperature'
|
|
local HYSTERESIS = 0.5 -- temp has to drop this value below setpoint before boiler is on again
|
|
local SMOOTH_FACTOR = 3
|
|
local LOGGING = true
|
|
|
|
return {
|
|
on = {
|
|
['timer'] = {
|
|
'every minute',
|
|
},
|
|
devices = {
|
|
TEMPERATURE_SENSOR,
|
|
SETPOINT_DEVICE
|
|
}
|
|
},
|
|
data = {
|
|
temperatureReadings = { history = true, maxItems = SMOOTH_FACTOR }
|
|
},
|
|
active = true,
|
|
execute = function(domoticz, item)
|
|
|
|
local avgTemp
|
|
local temperatureReadings = domoticz.data.temperatureReadings
|
|
local sensor = domoticz.devices(TEMPERATURE_SENSOR)
|
|
local current = sensor.temperature
|
|
local boiler = domoticz.devices(BOILER_DEVICE)
|
|
local setpoint = domoticz.devices(SETPOINT_DEVICE)
|
|
|
|
-- first check if the sensor got a new reading or the setpoint was changed:
|
|
if (item.isDevice) then
|
|
|
|
if (sensor.changed) then
|
|
-- sensor just reported a new reading
|
|
-- add it to the readings table
|
|
|
|
if (current ~= 0 and current ~= nil) then
|
|
temperatureReadings.add(current)
|
|
else
|
|
-- no need to be here, weird state detected
|
|
domoticz.log('Strange sensor reading.. skiping', domoticz.LOG_ERROR)
|
|
return
|
|
end
|
|
|
|
elseif (domoticz.devices(SETPOINT_DEVICE).changed) then
|
|
-- a new setpoint was set
|
|
if LOGGING then domoticz.log('Setpoint was set to ' .. item.state) end
|
|
else
|
|
-- no business here, bail out...
|
|
return
|
|
end
|
|
end
|
|
|
|
-- now determine what to do
|
|
if (setpoint.state == nil or setpoint.state == 'Off') then
|
|
boiler.switchOff()
|
|
return -- we're done here
|
|
end
|
|
|
|
local setpointValue = tonumber(setpoint.state)
|
|
|
|
-- determine at which temperature the boiler should be
|
|
-- switched on
|
|
local switchOnTemp = setpointValue - HYSTERESIS
|
|
|
|
-- don't use the current reading but average it out over
|
|
-- the past <SMOOTH_FACTOR> readings (data smoothing) to get rid of noise, wrong readings etc
|
|
local avgTemp = temperatureReadings.avg(1, SMOOTH_FACTOR, current) -- fallback to current when history is empty
|
|
|
|
if LOGGING then
|
|
domoticz.log('Average: ' .. avgTemp, domoticz.LOG_INFO)
|
|
domoticz.log('Setpoint: ' .. setpointValue, domoticz.LOG_INFO)
|
|
domoticz.log('Current boiler state: ' .. boiler.state, domoticz.LOG_INFO)
|
|
domoticz.log('Switch-on temperature: ' .. switchOnTemp, domoticz.LOG_INFO)
|
|
end
|
|
|
|
if (avgTemp >= setpointValue and boiler.state == 'On') then
|
|
if LOGGING then domoticz.log('Target temperature reached, boiler off') end
|
|
boiler.switchOff()
|
|
end
|
|
|
|
if (avgTemp < setpointValue and boiler.state == 'Off') then
|
|
if (avgTemp < switchOnTemp) then
|
|
if LOGGING then domoticz.log('Heating is required, boiler switched on') end
|
|
boiler.switchOn()
|
|
else
|
|
if LOGGING then domoticz.log('Average temperature below setpoint but within hysteresis range, waiting for temperature to drop to ' .. switchOnTemp) end
|
|
end
|
|
end
|
|
end
|
|
}
|